simplicity | capability | reliability

Home Products by Range Thickness Gauges T-Gage Series T-Gage IV DL
The T-GAGE IV DL is a hand-held Ultrasonic Thickness Gauge offering extended features and an internal Data Logger. Constructed to perform in the roughest of industry conditions the T-Gage IV DL can be calibrated to a variety of different materials using one or two point calibration.

The T-GAGE IV DL includes all the features and specifications of the T-Gage IV+, plus an Internal Data Logger (DL).
The data logger stores 1000 readings, held in 10 files with a 100 readings in each. The T-GAGE IV DL is also accompanied by the file transfer software,cable and an indicator of readings not logged.
Further Features include:
Data Send Options, interfacing with PCs/ printers.
Minimum thickness Alarm Mode.
Differential Mode
RS232 Output.
A dual element transducer is included. Application specific transducers are also available for Cast, Iron, Plastics, Fibreglass, Steel and Glass.
Small and portable, the T-Gage IV DL operates on 2 AA batteries for 200 hours plus.
All gauges in the T-GAGE series are covered by a 5 year limited warranty.
Applications include: Corrosion and Pitting, Tube and Pipe, Tanks and Boilers, Plastics/Polypropylene.
Weight: 285 g with batteries (10 ounces)
Size: 63.5w x 120.7h x 31.8d mm (2.5w x 4.75h x 1.25d inches)
Operating Temperature: -30° to 50°C (-20° to 120°F)
Case: Extruded aluminium body with nickel plated aluminium end caps.
Transducers: Dual element (transmit and receive). 1 - 10 MHz frequency range. Locking quick disconnect LEMO 00 connectors. 1.2m (4ft) cable.
Custom transducers available for special applications.
Overall Range: Measures from 0.63 to 500 mm (0.025 to 19.999 inches).
Toggle switch to select English or Metric units.
Resolution: 0.01 mm (0.001 inches)
Velocity Range: 1250 to 10,000 m/sec 0.0492 to 0.3937 in/μs
Four readings per second for single point measurements or 16 per second in Scan mode – captures the minimum thickness.
Enter the acceptable thickness value, unti will display +/- the difference from the entered value.
Enter a minimum acceptable thickness value. If the measurement falls below the minimum, a red LED will illuminate and an alert beeper will sound. If measurement is above minimum value set a green LED illuminates.
RS232 output sends data to serial printer, computer or other external storage devices.
Automatic numeric data logging system.
Capable of logging 1-1000 readings.
OBST indicates no reading